NPort 6110 Ethernet to RS-232/422/485 Modbus Gateway |
| NPort 6110 |
 |
Seamless Integration for Ethernet and Serial Modbus Devices |
Seamless Integration for Ethernet and Serial Modbus Devices Modbus is one of the most popular automation protocols in the world. Modbus protocol supports traditional RS-232/422/485 devices and newly developed Ethernet devices. Many industrial devices, such as PLCs, DCSs, HMIs, instruments, and meters, use Modbus as their communication standard. However, the Modbus protocol running over serial and Ethernet are so different that a communication gateway is needed as a bridge for integration. NPort 6110 supports one Ethernet and one software selectable RS-232/422/485 port that can connect with all kinds of Modbus devices. By translating Modbus/TCP (Ethernet) and Modbus /ASCII/RTU (Serial) protocols, a PLC with Ethernet can use the RS-232/422/485 interface to seamlessly communicate with instruments.
Powerful Operation Modes for Versatile Modbus Applications For Modbus protocol conversions, it is necessary to define a Master and Slave device, but unlike other Modbus Gateways, NPort 6110 allows users to configure Master/Slave for both the Ethernet and serial sides. Extra address mapping and exception parameters are supplied to ensure that most situations can be handled.
Windows Utility For Easy Setup and Traffic Monitoring NPort 6110 is powerful yet very easy to use. An intuitive Windows utility automatically searches for all available NPort 6110 units on the LAN. Traffic monitoring within the utility helps you troubleshoot any Modbus communication problem, such as connection status check, or address translation error check.
Features :
Modbus serial and Ethernet device integrationSupports Modbus/TCP Master device to link Modbus/ASCII/RTU slave devices (up to 31)Supports Modbus/ASCII/RTU master device to link Modbus/TCP slave devices (up to 12)Easy-to-use Windows utility for configuration over Ethernet10/100M fast Ethernet with automatic IP setting (DHCP) One software selectable RS-232/422/485 interfaceHigh speed serial up to 230.4 Kbps
| Specifications | | LAN | | Ethernet | 10/100 Mbps, RJ45, Auto MDI/MDIX | | Protection | Built-in 1.5 KV magnetic isolation | | | | Serial Interface | | Interface | RS-232/422/485, software selectable | | No. of Ports | 1 | | Port Type | Male DB9 | | Signals | RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND RS-422: Tx+, Tx-, Rx+, Rx-, RTS+, RTS-, CTS+, CTS-, GND 2-wire RS-485: Data+, Data-, GND | | Serial line protection | 15 KV ESD for all signals | | RS-485 data direction | Patented Automatic Data Direction Control (ADDC™) | | | | Serial Communication Parameters | | Parity | None, Even, Odd, Space, Mark | | Data bits | 7, 8 | | Stop bit | 1, 2 | | Flow control | RTS/CTS, XON/XOFF | | Transmission Speed | 1200 bps to 230.4 Kbps | | | | Software Features | | Internet Protocols | DHCP, BOOTP, TCP, UDP, IP, ICMP, ARP | | Modbus Protocols | Modbus/TCP, Modbus/ASCII, Modbus/RTU, Master/Slave modes supported | | Utilities | Modbus Gateway Configurator for Windows 95/98/ME/NT/2000/XP/2003 | | Configuration | Windows Utility via Ethernet | | | | | | Power Requirements | | Power input | 9 to 30 VDC | | Power consumption | 300 mA (at 12V max.) | | Ordering Information | | NPort 6110 | NPort 6110 Modbus/TCP to Serial Gateway with 100-240 VAC power adapt0r (US, Euro plugs included, 12V, 400 mA) |
|
|
|